GOM (NT) 系列瓦斯燃燒機熱功率涵蓋 3~40 萬大卡(約 35~465 kW),火力範圍寬廣,適用多種熱能設備。採中壓供氣系統,供氣管線較小、成本較低、施工容易,火力調整範圍廣;適用 LPG 桶裝瓦斯與 LNG 天然氣,無需變更既有設備。可搭配 UV 紫外線火焰監測控制器,異常時自動警報並遮斷電源與瓦斯。
Olympia 瓦斯燃燒機依熱功率級距與控制方式分為多個系列,依製程熱需求選用:
| 系列 | 熱功率級距 | 選用參考 |
|---|---|---|
| GOM (NT)(本頁) | 3~40 萬大卡 | 寬火力範圍 |
| GOM (N) | 3~40 萬大卡 | 寬火力範圍(不同控制) |
| ATS TG-30GA | 30 萬大卡 | 中型場域 |
| ATS (N) | 10~20 萬大卡 | 中小型場域 |
更大熱功率另有 AG、GLT、DHP、SDL 等系列。完整型號與大卡級距請見 Olympia Brand Page;可搭配 燃燒控制配件 使用。
燃燒機系列、熱功率與供氣方式應依製程熱需求、燃料種類與設備條件選定。請 提出產品詢問 取得選型建議。
| Burning capacity (kcal/h X 1000) | 100 |
| detect | probe |
| way to control | one paragraph |
| power supply | Voltage V: 220/220 Phase: 1 |
| Motor(KW) | 0.15 |
| Gas inlet size | 20A |
|
| Burning capacity (kcal/h X 1000) | 200 |
| detect | probe |
| way to control | one paragraph |
| power supply | Voltage V: 220/220 Phase: 1 |
| Motor(KW) | 0.25 |
| Gas inlet size | 20A |
|
| Burning capacity (kcal/h X 1000) | 300 |
| detect | probe |
| way to control | one paragraph |
| power supply | Voltage V: 220/380 Phase: 3 |
| Motor(KW) | 0.40 |
| Gas inlet size | 25A |
|
| Burning capacity (kcal/h X 1000) | 400 |
| detect | probe |
| way to control | one paragraph |
| power supply | Voltage V: 220/380 Phase: 3 |
| Motor(KW) | 0.40 |
| Gas inlet size | LPG: 25A LNG: 40A |
|
| fault state | reason | countermeasures |
|---|---|---|
| all do not move | 1. No power supply 2. The fuse is blown 3. Motor overload 4. Motor switch failure |
1. Check the total power 2. Check the control circuit for short circuit 3. Check whether the motor is faulty or replace it 4. Replace the switch |
| The motor will spin (but not fire) | 1. Dirty ignition stick 2. The ignition rod is in contact with the burner 3. No ignition sound and sparks 4. The air pressure switch is set too high |
1. Clean up 2. Adjustment 3. Check the ignition wire, electrode rod, ignition transformer or controller chassis feet 4. Adjustment |
| Lights up but goes out after a few seconds | 1. Dirty electric eyes 2. The sensor rod is in contact with the flame 3. Insufficient gas pressure 4. Sensing rod wear 5. The feet 13 and 14 of the controller chassis are too open |
1. Clean up 2. Adjustment 3. Adjustment 4. Replacement 5. Adjust the clamping |
| abnormal flameout | 1. There is ignition but no ignition 2. Electric eye or sensor rod failure |
1. The wind pressure is too large, adjust it down, the solenoid valve is faulty (updated), and there is no gas 2. Update the sensor or sensor stick |